PRODUCT
- HCS Series Card type PLC HCG Series Card type PLC HCM Series Card type PLC HCD2 Series Card type PLC HCM2 Series Card type PLC HCH2 Series Card type PLC HCG2 Series Card type PLC HCS2 Series Card type PLC
- H-BOX Series IoT Box H-BOX-M Series IoT Box HT3000-B Series IoT HMI HT3000-D Series IoT HMI
- HNC-808 series HNC-818 series HNC-848 series 606T CNC controller for Turnning Machine 606M CNC controller for Milling Machine 602T CNC controller for Turning Machine
- SV-E3 Series Synchronous Servo System HSD7 Series High-end Synchronous Servo Drive HSD2 Series Synchronous Servo Drive HSD6 Series Synchronous Servo Drive HSV-180AD AC380V Servo Drive HSV-180AS Spindle Servo Drive HSD2000 AC380V Servo Drive
- HV10 Series Mini Design Frequency Inverter HV100 Series High Performance Frequency Inverter HV480 Series High Performance Frequency Inverter HV610 Series High Performance Frequency Inverter HV580L Series Elevator Inverter HRS Series High Performance Soft Starter
- GM6 series spindle motor GM7 series spindle motor
- HSM (AC380V) Series Servo Motor HSM (AC220V) Series Servo Motor
- HNC Braking Unit Gear Boxes
- Rotary Encoder Proximity Sensor Photoelectric Sensor Area Sensor
1.3rd generation compact PLC
2.Modular PLC, input/output extension blocks can be connected, up to 7 HCA2C Series special function blocks can be connected.
3.Support all-serises HC8C right expansion
3.High efficiency with more speed, more performance, more memory, and new functions.
4.Built-in high speed processing and positioning
5.Exchangeable communication expansion boards that mount directly into the main unit (RS-232C)
6.Simultaneous memory cassette and display module mounting available
7.Integrated real-time clock
8.Easy programming with large instruction set
9.Large programming memory
HCA2C Basic Units
Specifications
Items |
Specification |
||||||
External power supply |
5 to 30V DC |
||||||
Resistance load |
Main unit |
Y000 to Y001 |
0.3A/1 point |
Make sure that the total load current of 16 resistance load points is 1.6A or less |
|||
Y002 to Y007 |
0.1A/1 point |
||||||
HCA8C-16EYT, HCA8C-32EYT |
0.1A/1 point |
||||||
HCA8C-16EYT-C |
0.3A/1 point |
Make sure that the total load current of 16 resistance load points is 1.6A or less. |
|||||
HCA8C-8EYT HCA8C-16EYT HCA8C-16EYR |
The total load current of resistance loads per common terminal should be the following value. 4points/common: 0.8A 8points/common: 1.6A |
||||||
HCA8C-8EYTR |
1A/1 point |
Make sure that the total load current of 4 resistance load points is 2A or less. |
|||||
Inductive load |
Main unit |
Y000 to Y001 |
7.2W/1 point (24V DC) |
Make sure that the total load of 16 inductive load points is 38.4W/24V DC or less. |
|||
Y002 to Y007 |
2.4W/1 point (24V DC) |
||||||
HCA8C-16EYT, HCA8C-32EYT |
2.4W/1 point (24V DC) |
||||||
HCA8C-16EYT-C |
7.2W/1 point (24V DC) |
||||||
HCA8C-8EYT, HCA8C-16EYT, HCA8C-16EYR |
12W/1 point (24V DC) |
||||||
HCA8C-8EYT-H |
24W/1 point (24V DC) |
||||||
Lamp load |
Main unit |
Y000 to Y001 |
0.9W/1 point (24V DC) |
Make sure that the total load of 16 lamp load points is 4.8W/24V DC or less. |
|||
Y002 to Y007 |
0.3W/1 point (24V DC) |
||||||
HCA8C-16EYT, HCA8C-32EYT |
0.3W/1 point (24V DC) |
||||||
HCA8C-16EYT-C |
1W/1 point (24V DC) |
||||||
HCA8C-8EYT, HCA8C-16EYT, HCA8C-16EYR |
1.5W/1 point (24V DC) |
||||||
HCA8C-8EYTR |
3W/1 point (24V DC) |
||||||
Open circuit leakage current |
0.1mA or less/30V DC |
||||||
ON voltage |
1.5V |
||||||
Response time |
OFF→ON |
Main unit |
Y000 to Y001 |
5µs or less/10mA or more (5 to 24V DC) |
|||
Y002 to Y007 |
0.2ms or less/100mA (24V DC) |
||||||
Extension blocks |
|||||||
ON→OFF |
Main unit |
Y000 to Y001 |
5µs or less/10mA or more (5 to 24V DC) |
||||
Y002 to Y007 |
0.2ms or less/100mA (24V DC) |
||||||
Extension blocks |
|||||||
Circuit insulation |
Photocoupler insulation |
||||||
Output operation display |
Main unit |
Monitored by the display module |
|||||
Extension blocks |
LED on panel lights when photocoupler is driven. |
Part names