INQUIRY

HOTLINE: +86 20 8489 8493

ONLINE QYY

E-MAIL: info@hncelectric.com

Product > Frequency Inverter > HV10 Series Mini Design Frequency Inverter
HV10 Series Mini Design Frequency Inverter
HV10 is the newest AC inverter with compact design from HNC Electric, thanks to advanced current vector control algorithm and newest hardware, HV10 has high stability and perfect motor control performance.

HV10 is the newest AC inverter with compact design from HNC Electric, thanks to advanced current vector control algorithm and newest hardware, HV10 has high stability and perfect motor control performance. Based on listening and understanding of customers’ requirement, HV10 supports full range of input voltage ( AC 120V / 220V / 380V / 460V and etc.) , complete functions for different countries and applications.

* Mini design housing suitable for micro automation such as packaging, labeling machine, conveyor belt etc.

* Double-line digital display, can display more content

* Detachable keyboard, external keyboard, convenient for customer debugging

* Powerful macro function, one-key setting, saving customer debugging time

* Built-in EMC C3 filter, stronger anti-electromagnetic interference ability

* Independent air duct design prevents dust from contacting the circuit board, better heat dissipation performance

* Installation back mounting system can insert the inverter directly into the rack 

* Programmable DI/DO/AI/AO as well as RS485 Modbus RTU make easy communication with other devices 

* Integrated PID function support most of water supply applications 

* Integrated multi-speed function support most of texitile application







1. Mini design housing suitable for micro automation such as packaging, labeling machine, conveyor belt etc.

2. Double-line digital display, can display more content

3. Detachable keyboard, external keyboard, convenient for customer debugging

4. Powerful macro function, one-key setting, saving customer debugging time

5. Built-in EMC C3 filter, stronger anti-electromagnetic interference ability

6. Independent air duct design prevents dust from contacting the circuit board, better heat dissipation performance

7. Installation back mounting system can insert the inverter directly into the rack 

8. Programmable DI/DO/AI/AO as well as RS485 Modbus RTU make easy communication with other devices 

9. Upgrade I/O(NPN/PNP compatible) can meet more application requirement.

10. Integrated PID function support most of water supply applications 

11. Integrated multi-speed function support most of texitile application

Model Definition:

Model

Input current (A)

Output current (A)

Adaptive motor

(KW)                  (HP)

G1 input voltage range: Single-phase AC220V±15%, 50 / 60 Hz

HV10-R40G1-2

5.9

2.5

0.4

0.5

HV10-R75G1-2

8.3

4.2

0.75

1

HV10-1R5G1-2

14.1

7.5

1.5

2

HV10-2R2G1-2

24

10

2.2

3

G2 input voltage range: Three-phase AC220V±15%, 50 / 60 Hz

HV10-R40G2

4.1

2.5

0.4

0.5

HV10-R75G2

5.3

4.2

    0.75

1

HV10-1R5G2

9

7.5

          1.5

2

HV10-2R2G2

15

10

          2.2

3

G3 input voltage range: Three-phase AC 380~440 (-15%~+10%), 50 / 60 Hz

HV10-R75G3

4.3

2.5

0.75

1

HV10-1R5G3

5.2

3.7

1.5

2

HV10-2R2G3

6.0

5.1

2.2

3

HV10-004G3

13.5

9.5

4.0

5

HV10-5R5G3

19.5

14

5.5

7.5

G4 input voltage range: Three-phase AC 460~480 (-15%~+10%), 50 / 60 Hz

 

HV10-R75G4

4.1

2.5

0.75

1

HV10-1R5G4

4.9

3.7

1.5

2

HV10-2R2G4

5.7

5.0

2.2

3

HV10-004G4

11

8

4.0

5

HV10-5R5G4

15

10

5.5

7.5

Standard Specification:

Input

Rated voltage , Frequency

Three-phase (G3/G4 series) 380V-480V, 50/60HZ

Single&Three-phase (G1/G2 series)  220 V: 50/60 Hz

Allowable range of voltage variation

Three-phase (G3 series) : AC 380~440 (-15%~+10%)

Three-phase (G4 series) : AC 460~480 (-15%~+10%)

Single&Three-phase (G1/G2 series) : AC220V±15%

Output

Voltage

G1/G2 series; 0220V, G3 series; 0440 V, G4 series; 0480 V

Frequency

0999.9HZ

Overload capacity

110% long-term150% 1 minute180% 5 seconds

Control mode

V/F control, Vector control

Control characteristic

Frequency setting resolution

Analog input

0.1% of the maximum output frequency

Digital settings

0.1HZ

Frequency accuracy

Analog input

Within 0.2% of the maximum output frequency

Digital input

Within 0.01% of the set output frequency

V/F control

V/F curve (voltage frequency characteristic)

Three ways: the first is linear torque characteristic curve, the second is square torque characteristic curve, and the third is user-set V/F curve

Torque boost

Manual setting: 0.0 30.0% of rated output

Automatic lifting: automatically determine the boost torque according to the output current and motor parameters

Automatic current and voltage limiting

Whether in acceleration, deceleration or stable operation, the motor stator current and voltage can be automatically detected, which can be suppressed within the allowable range according to the unique algorithm to minimize the possibility of system fault tripping

Sensorless vector control

voltage frequency characteristic

Automatically adjust output voltage-frequency ratio according to motor parameters and unique algorithm

Torque characteristic

Starting torque:

100% rated torque at 5.0Hz (VF control)

150% rated torque at 0.5Hz (Vector control)

Current and voltage suppression

Full-range current closed-loop control, completely avoiding current impact, with perfect overcurrent and overvoltage suppression function

Undervoltage suppression during operation

Especially for users with low grid voltage and frequent fluctuation of grid voltage, the system can maintain the longest possible operation time according to the unique algorithm and residual energy allocation strategy even in the range below the allowable voltage

Typical function

Multi-stage speed operation

7-stage programmable multi-stage speed control and multiple operation modes are optional.

PID control

RS485 communication

Built-in PID controller (preset frequency). Standard configuration RS485 communication function, multiple communication protocols can be selected, with linkage synchronous control function

Frequency setting

Analog input

DC voltage 0 10 V, DC current 0 20 mA (upper and lower limits are optional)

Digital input

Operation panel setting, RS485 interface setting, UP/DW terminal setting, and various combination settings with analog input can also be made.

Output signal

Digital output

1 OC output and 1 relay output (TA,TC), with up to 17 functions

Analog output

1 AO, the output range can be flexibly set between 0 20mA or 0 10V, which can realize the output such as set frequency and output frequency.etc

Automatic voltage stabilizing operation

According to the needs, three modes can be selected: dynamic voltage stabilization, static voltage stabilization and non-voltage stabilization, so as to obtain the most stable operation effect

Acceleration / deceleration time setting

0.1S999.9min can be set continuously

Brake

Energy consumption braking

Energy consumption braking starting voltage, return difference voltage and energy consumption braking rate can be continuously adjusted

DC brake

Starting frequency of DC braking during stop: 0.00 [00.05] upper limit frequency

Braking time: 0.0 30.0s; Braking current: 0.0% 50.0% of rated voltage of motor

Low noise operation

The carrier frequency is continuously adjustable from 2.0 kHz to 20.0 kHz to minimize the noise of the motor

Counter

One internal counter is convenient for system integration

Operating function

Upper and lower limit frequency setting, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increment and decrement control, fault self-recovery operation, etc

Display

Running status

Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, PID feedback , analog input and output, etc

Alarm content

Record a number of operating parameters such as output frequency, set frequency, output current, output voltage, DC voltage and module temperature during the latest fault

Protection function

Overcurrent, overvoltage, undervoltage, module failure, electronic thermal relay, overheating, short circuit, internal memory failure, etc.

Environment

Ambient temperature

-10℃  +40℃ (when the ambient temperature is 40℃ 50℃, please use it at a reduced level)

Ambient humidity

5% 95% RH, no water condensation

Surrounding environment

Indoor (no direct sunlight, corrosion, flammable gas, oil mist, dust, etc.)

Altitude

Derating for use above 1000 meters, every 1000 meters up derating 10%

Structure

Protection grade

IP20

Cooling mode

Air-cooled with fan control



    Product Outline, Mounting Dimension, and Weight

    

Voltage

 

 level

Model

Outline construction and installation dimensionmm

Weight

 

kg

W

H1

D

W1

H2

Mounting hole(d)

1PH 220V

HV10−R40G1-2

60

160

134

78

170

4

0.9

HV10−R75G1-2

HV10-1R5G1-2

HV10−2R2G1-2

3PH 220V

HV10−R40G2

HV10−R75G2

HV10−1R5G2

HV10-2G2G2

3PH 380V 

HV10−R40G3

HV10−R75G3

HV10−1R5G3

HV10−2R2G3

HV10−004G3

78

200

152

95

212

4

1.3

HV10−5R5G3


Series Model Download
Frequency Inverter HV10 Series Frequency Inverter Catalog-V2.1
Frequency Inverter HV10 Series Frequency Inverter User Manual-V8.1
About HNC
Company Overview Vision and Mission HNC Growth History
Product
PLC HMI CNC Controller Servo Drive Frequency Inverter Spindle Motor AC Servo Motor Accessories Sensor
Solution
Packaging & Printing CNC Machine Tool Textile Fan & Pump Converting Elevator Crane Plastic Industry
Service
DownLoad FAQ Warranty
News Center
HNC news